Working principle
ODS use thermocouple component as a sensor to search the temperature of pilot flame in order to drive the electromagnetic valve,when the space is hypoxia(O-17%~19%),the flame temperature is under 400°C,there is not enough potential to open the gas valve ,so then the valve will be closed to keep safe
Usage and charaters:
Product Name: Pilot burner assembly
Item No: ESOD-002
Application country: Europe, North America
Certification:CE/CSA
Applicable gas families:LPG/propane/butane
Flame Numbers: Two flame